| Warnings | Count |
|---|---|
| Total | 0 |
| Waived Violations | Count |
|---|---|
| Un-Routed Net Constraint ( (All) ) | 20 |
| Total | 20 |
| Un-Routed Net Constraint ( (All) ) |
|---|
| Un-Routed Net Constraint: Net GND Between Pad J11-4(-1037mil,-467.441mil) on Top And Pad J11-2(-1037mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J11-5(-1312mil,-467.441mil) on Top And Pad J11-3(-1312mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J1-2(-1865.441mil,137.5mil) on Top And Pad J1-4(-1865.441mil,137.5mil) on Bottom Waived by Jessica Li at 5/11/2026 1:48:52 AM although they appear unrouted as of now after soldering connector on it, the two grounds will become routed |
| Un-Routed Net Constraint: Net GND Between Pad J12-4(-1312mil,467.441mil) on Top And Pad J12-2(-1312mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J12-5(-1037mil,467.441mil) on Top And Pad J12-3(-1037mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J1-3(-1865.441mil,-137.5mil) on Top And Pad J1-5(-1865.441mil,-137.5mil) on Bottom Waived by Jessica Li at 5/11/2026 1:48:52 AM although they appear unrouted as of now after soldering connector on it, the two grounds will become routed |
| Un-Routed Net Constraint: Net GND Between Pad J21-4(-254mil,-467.441mil) on Top And Pad J21-2(-254mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J21-5(-529mil,-467.441mil) on Top And Pad J21-3(-529mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J2-2(1865.441mil,-137.5mil) on Top And Pad J2-4(1865.441mil,-137.5mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J22-4(-529mil,467.441mil) on Top And Pad J22-2(-529mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J22-5(-254mil,467.441mil) on Top And Pad J22-3(-254mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J2-3(1865.441mil,137.5mil) on Top And Pad J2-5(1865.441mil,137.5mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J31-4(529mil,-467.441mil) on Top And Pad J31-2(529mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J31-5(254mil,-467.441mil) on Top And Pad J31-3(254mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J32-4(254mil,467.441mil) on Top And Pad J32-2(254mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J32-5(529mil,467.441mil) on Top And Pad J32-3(529mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J41-4(1312mil,-467.441mil) on Top And Pad J41-2(1312mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J41-5(1037mil,-467.441mil) on Top And Pad J41-3(1037mil,-467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J42-4(1037mil,467.441mil) on Top And Pad J42-2(1037mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |
| Un-Routed Net Constraint: Net GND Between Pad J42-5(1312mil,467.441mil) on Top And Pad J42-3(1312mil,467.441mil) on Bottom Waived by Jessica Li at 5/10/2026 1:46:07 AM Although the grounds of a SMA connector are not routed togther, they will be electrically connected through the SMA. |